Glidevale Protect, one of the UK’s leading manufacturers of external wall breather membranes, welcomes the recent updates to Structural Timber Association’s STA Advice Note 18 which highlight the importance of providing specifiers with trusted, and tested, technical product information.

First launched in 2019, STA Advice Note 18 – ‘Breather membranes to structural walls’ is a valuable resource for contractors and specifiers involved in structural timber construction projects and the wider offsite construction market. The guide provides detailed information on the use of breather membranes in terms of watertightness, exposure, thermal performance and fixing requirements.

The new amendments to the document were published in April 2023 and have been compiled in collaboration with several specialist manufacturers including representatives from Glidevale Protect.

The revised STA Advice Note 18 provides enhanced guidance on watertightness and specifically the use of W1 and W2 rated external breather membranes. A new section on ‘site-specific exposure to wind-driven rain’ aims to clarify how to assess if a site is in a very severe area and if it would require a W1 rated breather membrane to provide the necessary resistance against water penetration. Guidance maps from BRE and NHBC are also included to highlight very severe areas of the UK where a W1 membrane is recommended. As one of the contributors to both the original and revised STA Advice Note 18, Glidevale Protect is well placed to assist specifiers and designers in choosing the most appropriate product for their project and offers a full range of both W1 and W2 rated reflective and non-reflective breather membranes for external walls.

As outlined in the original version of the STA Advice Note 18, the new guidance looks specifically at the specification and installation of external breather membranes for cavity facing structural wall panels. The recent updates highlight the need for all manufacturers to be able to verify all product claims, including for reflective membranes to be tested to BS EN 15976 and to claim aged thermal resistance figures which are fully independently certified by a third-party accredited body. Glidevale Protect is committed to providing full technical transparency to its customers and fully supports the renewed focus on providing specifiers with reliable technical information for external membranes which accurately reflects real life performance figures.  In compliance STA Advice Note 18, its product range of external breather membranes is tested and certified by a UKAS accredited, independent third party. In line with the recommendations outlined in the guidance, Glidevale Protect is also a passionate advocate of improving the way manufacturers communicate the technical performance of a product and specifically, clarifying if the quoted figures are based on aged or unaged values. As well as providing full transparency on the testing of its products, Glidevale Protect’s best practice ensures all its results take into account any brand printing on the low-emissivity surface and in addition, the aged thermal resistance values achieved are based on the membrane installed with the appropriate maximum horizontal fixing centres of 600mm, both which are detailed in STA Advice Note 18.

Specifiers can obtain a copy of the STA Advice Note 18 by contacting Glidevale Protect’s technical team directly at info@glidevaleprotect.com or by calling +44 (0)161 905 5700.

Further guidance on the specification of external breather membranes as part of the wall, floor or roof build-up within structural timber construction, including free U-value calculations condensation risk analysis and take offs, is also available from Glidevale Protect’s technical team. Follow Glidevale Protect on LinkedIn.

Related products

Protect TF200 Thermo insulating breather membrane

View product

Protect Thermo Extreme insulating breather membrane

View product

Protect TF200 Extreme breather membrane

View product

Protect TF200 breather membrane

View product

Protect 5000 Façade wall membrane

View product

You may also be interested in…

Glidevale Protect publishes roof space ventilation technical guidance

Read more

Glidevale Protect boosts sustainability at Swansea social housing scheme

Read more

Glidevale Protect joins the roster of roofing professionals as NFRC members

Read more

Talk to us

Contact us today to discover more about our extensive range of building product solutions and the technical support services we can offer.

Get in touch

Glidevale Protect is a division of Building Product Design Ltd.

Other subsidiaries include ventilation systems specialist Passivent and Kingfisher Louvres, manufacturer of aluminium louvres systems.

Important Notice

Please be vigilant of fraud/cyber crime. If you receive an email from our parent company Building Product Design Ltd, please check that the email address from the sender ends in '@buildingproductdesign.com' and any phone number given is 0161 905 5700.

If you receive any emails ending in '@bpdgroup.co.uk' or '@bpd.co.uk', these are NOT legitimate, and you should contact us as soon as possible at info@buildingproductdesign.com.

Site by Harris